Multímetro 8558A de 8,5 dígitos para entornos de pruebas de fabricación y automatización de sistemas:
La plataforma 85x8A también incluye el multímetro 8558A de 8,5 dígitos que ofrece un subconjunto de funciones y características del modelo 8588A con una precisión y una velocidad extremadamente competitivas. El 8558A digitaliza 5 millones de lecturas por segundo para la automatización rápida de sistemas de alta resolución en laboratorios y entornos de pruebas de fabricación.
The 8558A 8.5-digit multimeter offers 5 mega-samples-per-second high resolution digitizing for system automation in labs and manufacturing test environments. Fluke’s new high-speed system design and the industry’s fastest direct digitizing capability enable significant throughput increases for many automated system applications that require a combination of highest speed and best accuracy. The superb accuracy is delivered over a wide measurement range, over nine functions, with an intuitive user interface on a color display.
The 8558A shares the same platform as the fully loaded 8588A Reference Multimeter. The platform features a common intuitive user interface with easy-to-navigate menu structure for all configuration and matching SCPI-compliant commands for automated environment. The 8588A platform guarantees a minimum of 100,000 readings per second at 4.5 digits across GPIB, USBTMC or Ethernet, and an onboard data memory that can hold up to 15 million readings.
DC voltage
100 mV to 1000 V, (1050V max)
2.02x full scale
Maximum resolution: 1 nV
4.0 μV/V (95 %) 5.7 μV/V (99 %), 1 year
0.5 μV/V (95 %) 0.65 μV/V (99 %), 24 hour stability
0 to 10 s reading aperture (200 ns resolution)
DC current
10 uA to 2 A (8558A)
2.02x full scale
Maximum resolution: 1 pA
9 μA/V (95 %), 12 μA/V (99 %), 1 year
0 ns to 100 s reading aperture
AC voltage
10 mV to 1000 V, 1 Hz to 10 MHz, (1050 Vrms max)
2.02x full scale Vpp, 1.2x full scale Vrms
Maximum resolution: 1 nV
80 μV/V (95 %), 103 μV/V (99 %), 1 year
AC current
10 uA to 30 A (8588A only; 2 A for 8558A)
2.02x full scale Vpp, 1 Hz to 100 kHz 1.2x full scale Vrms
Maximum resolution: 1 pA
300 μA/V (95 %), 387 μA/V (99 %), 1 year
Resistance
1Ω to 10 GΩ (20 GΩ max)
2.02x full scale
Maximum resolution: 10 nΩ
10 μΩ/Ω (95 %), 13 μΩ/Ω (99 %), 1 year
Low current mode, high voltage mode and Tru Ohms™
Digitize V
100 mV to 1000 V, (1050 V max)
2.02x full scale
Maximum resolution: 18 bits
5 mega-samples per second sample rate
Up to 20 MHz bandwidth
Digitize I
10 μA to 30 A (8588A only; 2 A for 8558A)
2.02x full scale
Maximum resolution: 18 bits
5 mega-samples per second sample rate
Up to 4 MHz bandwidth
Frequency or period
Voltage, up to 10 MHz
Current, up to 100 kHz
Frequency up to 100 MHz on BNC
0.5 μHz/Hz, 1 year
Capacitance
1 nF to 100 mF
400 μF/F, 1 year
Temperature
PRT and thermocouple
5 mK, 1 year
RF power
Rhode & Schwarz NRP series DC I and AC I external shunt
DC I and AC I external shunt
A40B and any other external shunt
Reading speed
1 reading /s @ 8.5 digit into memory
100,000 readings /s @ 4.5 digit into memory
Up to 500,000 readings /s into volatile memory in digitize V and I
Up to 500,000 readings/s transfer through USB in binary format
Measurement memory
15 million readings
7.5 million readings with time stamp
GPIB, USBTMC, Ethernet
Native SCPI compliant remote commands
8508A and 3458A emulation mode
Fully support MET/CAL™ calibration procedures library in Fluke 8508A emulation
IVI driver
USB thumb drive for convenient data transfer in .csv format
Trigger mechanisms
Manual trigger
External BNC Trig In and Trig Out
Internal or level trigger
Timer trigger
Epoch trigger
Line trigger
BUS trigger